Home Messtechnik Produkte ACR Systems Inc. SmartReader SmartReader3 (SR-003)

SmartReader3 (SR-003)

The Smart Reader3 data logger easily and conveniently records AC current. Simply connect the data logger to three ACR current probes (Which are clamped around power leads) and begin recording three-phase systems or related equipment simultaneously. The probes allow accurate readings to be taken without interrupting any circuits. The logger also records ambient temperature.

Product Specifications

No. of Channels: Four

  • - One for ambient temperature
  • - Three for AC current (with ACR current probes)

Current Ranges:¹

  • - 5, 25, 100 and 250 Amps - With A60FL (60 Hz) and A65FL (50 Hz) current probes
  • - 10, 50, 250 and 500 Amps - With A70FL (60 Hz) and A75FL (50 Hz) current probes

¹ Up to 3000 Amps with the ACR CT-50-1 current transformer

  • Accuracy: + / - 4% F.S. above 10% of range
  • Memory Size: 32 KB
  • Accessories: ACR AC Current Probes, ACR Ct-50-1 Current Transformer

 Übersicht über die SmartReader 3