Home Messtechnik Produkte ACR Systems Inc. OWL

OWL

Product Specifications

OWL data loggers shre many common features. For further specifications on individual models, refer to the links.

  • Size: 60 mm x 48 mm x 19 mm (2.4" x 1.9" x 0.7")
  • Weight:
  • 54 g (1.9 oz) - all models expect OWL 100-Poly
  • 80 g (2.8 oz) - OWL 100-Poly (water-resistant model)
  • Case Material:
  • Noryl® plastic - all models expect OWL 100-Poly
  • Polyurtheane - OWL 100-Poly (water-resistant-model)
  • External Connector: Removable snap type connector
  • Mounting: Locking eyelet or magnetic backing
  • Operating Limits:-40 to 70ºC (-40 to 158ºF) and 0 to 95% RH (non-condensing) on non-wteright models
  • Clock Accuracy: +/- 2 seconds per day
  • Battery: 3.6 volt Lithium
  • Battery Life: 10 years under normal use (factory replaceable)
  • Memory Size: 32 KB (32,767 readings)
  • Sampling Methods:
  • Delayed start to trigger start:
  • 1. Continuous (First-in, First-out)
  • 2. Stop when full (Fill-then-stop)
  • Sampling Rates: User selectable rates from 5 per second to once every 12 hours
  • Resolution: 8-bit (1 part in 256)
  • Communication: Optical - send/receive data from up to 1" between logger and interface cable (with no obstructions)
  • Alarm Type: Optical - flashing red LED
  • PC Requirements: IBM PC or 100% compatible running Windows®3.1, ´95, ´98, 2000, Me, NT or XP with at least 2 MB RAM, 2 MB of hard disk space and one free serial port
  • Software Requirements: TrendReader®Standard
  • Certifications and Standards:
  • - Certified to CE standatd EN50082-1: 1992 (European Generic Immunity) covering ESD, RFI and EDT/B
  • - Meets CE standtads EN55011 Class B: 1991 (European Radiated Emissions) and CISPR Class B: 1191 (International Radiated Emissions)
  • Resistance to X-Rays:
  • - Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D (about 100 times that of an airport x-ray machine)
  • - Tested for protection against Gamma Ray (equivalent to 0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second exposure to object distance 5"