Product Specifications
OWL data loggers shre many common features. For further
specifications on individual models, refer to the links.
-
Size: 60 mm x 48 mm x 19 mm (2.4" x 1.9" x
0.7")
- Weight:
- 54 g (1.9 oz) - all models expect OWL 100-Poly
- 80 g (2.8 oz) - OWL 100-Poly (water-resistant model)
- Case Material:
- Noryl® plastic - all models expect OWL 100-Poly
- Polyurtheane - OWL 100-Poly (water-resistant-model)
- External Connector: Removable snap type connector
- Mounting: Locking eyelet or magnetic backing
-
Operating Limits:-40 to 70ºC (-40 to 158ºF) and 0 to
95% RH (non-condensing) on non-wteright models
- Clock Accuracy: +/- 2 seconds per day
- Battery: 3.6 volt Lithium
-
Battery Life: 10 years under normal use (factory
replaceable)
- Memory Size: 32 KB (32,767 readings)
- Sampling Methods:
- Delayed start to trigger start:
- 1. Continuous (First-in, First-out)
- 2. Stop when full (Fill-then-stop)
-
Sampling Rates: User selectable rates from 5 per second
to once every 12 hours
- Resolution: 8-bit (1 part in 256)
-
Communication: Optical - send/receive data from up to
1" between logger and interface cable (with no
obstructions)
- Alarm Type: Optical - flashing red LED
-
PC Requirements: IBM PC or 100% compatible running
Windows®3.1, ´95, ´98, 2000, Me, NT or XP with at least
2 MB RAM, 2 MB of hard disk space and one free serial port
- Software Requirements: TrendReader®Standard
- Certifications and Standards:
-
- Certified to CE standatd EN50082-1: 1992 (European Generic
Immunity) covering ESD, RFI and EDT/B
-
- Meets CE standtads EN55011 Class B: 1991 (European
Radiated Emissions) and CISPR Class B: 1191 (International
Radiated Emissions)
- Resistance to X-Rays:
-
- Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D (about 100 times that
of an airport x-ray machine)
-
- Tested for protection against Gamma Ray (equivalent to
0.137-1.38 mega volts) IR 192 - 28 curies @ 30 second
exposure to object distance 5"