Home | Produkte: | ACR Systems Inc. | IAQ Logger

IAQ Logger

The IAQ Logger, when combined with the Telaire 7001 Handheld CO2 Monitor, records the three leading indicators of indoor air quality: (1) temperature, (2) relative humidity, and (3) carbon IAQ100dioxide. This IAQ solution is ideal for those applictions requiring long-temperature and CO2 on the Telair´s large, easy-to read display.

Prdouct Specifications

  • Size: 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
  • Weight: 110 g (3.75 oz)
  • Case Material: Noryl®plastic
  • Mountign: Magnetic backing or looking eyelet
  • Operating Limits: -40 to 70ºC (-40 to 158ºF) and 0 to 95% RH (non-condensing)
  • Clock Accuracy: +/- 2 seconds per day
  • Battery or Power Supply: 3.6 volt Lithium
  • Battery Life: 10 years under normal use
  • No. of Channels: five
  • - One for ambient temperature
  • - One for relative humidity
  • - One for carbon dioxide
  • - Two for temperature and/or RH (with ACR thermistor probes or ACT temp/RH probe)
  • Memory Size: 32 KB (32.67 readings)
  • Sampling Methods:
  • 1. Continuous (First-in, First-out)
  • 2. Stop when full (Fill-then-stop)
  • Sampling Rates: User selectable rates from 8 seconds to once every 5 days
  • Resolution: 8-bit (1 part in 256)
  • PC Requirements: IBM PC or 100% compatible running Windows® 3.1, `95, `98, 2000, Me, Nt or XP with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
  • Software Requirements: Trand Reader®Standard


TELAIRE 7001

  • Size: 170 mm x 80 mm x 40 mm (6.7" x 3.1" x 1.6")
  • Weight: 280 g (9.9 oz)
  • Case Material: ABS plastic
  • Mounting: Pull-out stand
  • Operating Limits: 0 to 50ºC (32 to 122ºC) and 0 to 95% RH (non-condensing)
  • Power Supply: 6 VDC from external AC/DC adapter (included) or 4 AA Batteries (not included)


Sensor Specifications

  • Temperature Sensor (in IAQ Logger):
  • Type: NTC Thermistor
  • Range: -40 to 70ºC (-40 to 158ºF)
  • Accuracy: +/- 0.2ºC over the range of 0 to 70ºC (+/- 0.2ºC over the range of 32 to 158ºF)
  • Resolution: 0.4ºC(0.7ºF) @ 25ºC; better than 1ºC (1.8ºF) between -25 and 70ºC (-13º and 158ºF); better than 2.0ºC (3.6ºF) between -40 and -25ºC (-40ºF and -13ºF)


  • RH Sensor (in IAQ Logger):
  • Type: Capacitive thin polymer film
  • Range: 0 to 95% RH
  • Accuracy: +/- 4% RH from 10 to 90º (-20 to 40ºC [-40 ti 104ºF])
  • Resolution: Better than 0.4º RH between 25 and 60º RH at 25ºC (77ºF)


  • CO2 Sensor (in Telaire:)
  • Range: 0 to 4,000 ppm voltage output, 0 to 10,000 ppm display
  • Sensitivity: +/- 1 ppm
  • Accuracy: +/- 50 ppm or +/- 5 % reading (whichever is greater)
  • Repeatability: +/- 20 ppm